Arrow Hunter plus V3 Fixed Wall Mount Clamp-on Flowmeter

The ECHO Arrow Hunter PLUS  range of non-invasive flow meters utilize Transit-time ultrasonic technology for the accurate flow measurement of clean or dirty liquids in full pipes.  The transducers can be installed on any plastic, PVC, ductile iron with concrete liners, mild or stainless steel, or any other material (except pure concrete pipe).

The Arrow Hunter PLUS – FIXED (AH+FX) is designed for permanent installation on applications where advanced options and configurations are required.The flow meter includes a variety of input and output options for diverse measurement requirements.

Category:

Description

• Non-invasive flow measurement for clean or dirty liquids

 

• Advanced Transit-time Technology with +/- 0.5% Accuracy

 

• Measures all metal, composite & plastic pipes 0.25″ – 118″  diameters with or without liners

 

• Dual DSP Microprocessor with digital signal noise rejection

 

• Wall-mount NEMA 4X enclosure with graphical display

 

• Easy to install clamp-on sensors

 

The ECHO Arrow Hunter PLUS range of non-invasive flow meters utilize Transit-time ultrasonic technology for the accurate flow measurement of clean or dirty liquids in full pipes.  The transducers can be mounted on any pipe material (plastic, rubber, metal) except pure concrete pipe which is very rare.

The Arrow Hunter PLUS – FIXED (AH+FX) is designed for permanent installation on applications where advanced options and configurations are required.The flow meter includes a variety of input and output options for diverse measurement requirements.

The measurement of flow is based on the principle that sound waves are influenced by a flowing medium. Measurements are made by penetrating the pipe with ultrasound and measuring the frequency variations and phase shifts of the signals received.This measuring technique has no effect on the flowing medium. There is no pressure loss in the pipe and no wear on components of the measuring device.

The ultrasonic sensors are clamped onto the outside of the pipe, thus eliminating the need to dismantle the pipe work and interrupt the process.The AH+FX can be applied to any type of metal or plastic pipe with or without a liner carrying clean or dirty liquids.We have several transducers to chose from depending on pipe size, process temperature and required approvals.

The Arrow Hunter PLUS – FIXED  (AH+FS) offers dual channel and Energy BTU measurement capabilities.

ECHO Process Instrumentation offers a 60 day Performance Guarantee! 

Downloads

Specs

Techincal Specs: Arrow Hunter Plus FX V3

General

Measuring principle : Ultrasonic Transit-time
Flow
 velocity range 0.03 … 82 ft/s (0.01 … 25 m/s)

Resolution : 0.00082 ft/s (0.25 mm/s)
Repeatability : 
0.15 % of measured value ±0.015 m/s
Accuracy : 
Volume flow :  ± 0.5% factory calibrated (process conditions can reduce accuracy),
±
 0.5% of measured value with process calibration
                 Flow velocity : ± 0.5 % of measured value
Turn
 down ratio : 1/100
Max particulates : 
< 10 % of volume

Flow transmitter

Enclosure : Wall mounted housing

Protection rating : NEMA 4X (IP 66 according EN60529)
Operating temp. : 
14 …140 °F (-10 … 60 °C)
Housing material : 
Plastic, ABS, Polycarbonate (transparent front door only)
Flow channels : 
1 (optional 2 channels with Full Spec)
Power
 supply : 100 … 240 VAC 50/60 Hz, 9 … 36 VDC
Display : 
LCD graphic display, 128 x 64, backlight
Dimensions : 
9.3 H x 10.1 W x 5.7 D inch (237 H x 258 W x 146 D mm)
Weight : 
Approx. 5 lbs (2.3 kg)
Power consumption: 
< 5 W
Signal damping : 
0 … 99 s
Measurement rate 
10 … 1000 s-1
Operating languages: English, German, French, Spanish
Response
 time : 1 s, faster rates upon request
Calculation
 functions: Full Spec Version Dual Mode: Average/difference/sum

Quantity and units of measurement

Volumetric flow rate : m3/h, m3/min, m3/s, l/h, l/min, l/s, USgal/h, USgal/min, USgal/s, USMGD, bbl/d, bbl/h, bbl/min, bbl/s
Flow
 velocity : m/s, ft/s, inch/s
Mass
 flow rate : g/s, t/h, kg/h, kg/min
Volume/ Mass : 
m³, l, US gal, bbl / g, kg, t
Energy
 : BTU, MBTU, MMBTU, W, kW, MW, J, kJ, MJ (only with Full Spec option)

 

Internal data logger

Storage capacity : approx. 30,000 samples (128 kByte), optional > 100,000 samples (512 kByte)
Logging
 data : All measured and totalized values

Communication

Serial interface : RS 232, (optional RS 485)
Data : 
Instantaneous measured value, parameter set and configuration, logged data

Software AH+ PC Software

Functionality : Downloading of measured values/parameter sets, graphical presentation, list format, export to third party software, on-line transfer of measured data
Operating
 systems Windows 2000, NT, XP, Vista, 07

Process Inputs (Galvanically isolated)

Temperature : PT 100, range – 50 … 400 °C
Current : 
0 … 20 mA active or 4 … 20 mA passive, U = 30V, R= 50Ω, accuracy 0.1% MV

Process outputs (Galvanically isolated)

Current : 0/4 … 20 mA, active (RLoad < 500 Ω), 16 bit resolution, U=30V, accuracy = 0.1%
Voltage : Optional 0 … 10V, Ri = 500Ω

Digital (pulse) : 1 Open Collector, width 30 … 999 ms, U = 24 V, Imax = 4mA
Digital (relay) : 2 Form “C” SPDT, U=48V Imax=250mA , as Alarm or Fault (programmable

 

Clamp-on Sensors

Type XTT+SM

Diameter range : 0.25 … 9.8 inch (6 … 250 mm)
Dimensions : 
1.7 x 0.7 x 0.8 inch (43x18x22mm)
Material : 
Stainless Steel
Temperature range
 :   Type XTT+SM: -22 … 266 °F (-30 … 130 °C)

  Type XTT+SM-EX: -4 … 248 °F (-20 … 120 °C)

Protection rating : NEMA 4X (IP 66 acc. EN 60529), Optional NEMA 6P (IP 68) submersible

Hazardous rating :     Type XTT+SM: Standard is General Purpose

Type XTT+SM-EX: ATEX Approved Ex mb IIC T4 – T6
Sensors are suitable for Zone 1 & 2. Transmitter must be located in safe area.

Type XTT+LG

Diameter range : 1.96 … 118 inch (50 … 3000 mm)
Dimensions : 
2.3 x 1.2 x 1.3inch (60x30x34 mm)
Material : 
Stainless Steel

Temperature range :   Type XTT+LG: -22 … 266 °F (-30 … 130 °C)

  Type XTT+LG-EX: -4 … 248 °F (-20 … 120 °C)

Protection rating : NEMA 4X (IP 66 acc. EN 60529), Optional NEMA 6P (IP 68)

Hazardous rating :     Type XTT+LG: Standard is General Purpose

       Type XTT+LG-EX: ATEX Approved Ex mb IIC T4 – T6
Sensors are suitable for Zone 1 & 2. Transmitter must be located in safe area.

Reviews

There are no reviews yet.

Be the first to review “Arrow Hunter plus V3 Fixed Wall Mount Clamp-on Flowmeter”

Your email address will not be published. Required fields are marked *